Impulse 463N Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Impulse 463N. Impulse 463N User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 109
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1

Sealevel Systems, Inc. Sealevel.com Phone 864.843.4343

Strona 2

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 10 S Series (RS-232) The KT119 includes a modular adapter with a DB9 female connector that p

Strona 3

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 100 SeaLATCH USB Connectors SeaLATCH locking USB cables integrate a small thumbscrew into ea

Strona 4

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 101 SeaI/O 120VAC to 24VDC @ 250mA Wall Mount Power Supply (Part# TR112) The TR112 is a wal

Strona 5

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 102 100-240VAC to 24VDC @ 2.1A DIN Rail Power Supply (Part# PS103) The PS103 is an AC/DC DI

Strona 6

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 103 100-250VAC @ 2.7A Desktop Power Supply with US Power Cord (Part# TR108-US) (Part# TR108)

Strona 7

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 104 1U 19 Inch Rack Tray (Part# RK1U) The RK1U is a 1U rack tray for conveniently mounting y

Strona 8

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 105 CAT5 Crossover Cable, 7' in Length (Part# CA251) 7‟ Yellow Crossover Cable. Used to

Strona 9

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 106 SeaI/O DB9 Female to RJ45 Adapter (RS-232 Pinout) and CAT5 7' Patch Cable (Blue) (P

Strona 10

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 107 A sudden electrostatic discharge can destroy sensitive components. Proper packaging and

Strona 11

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 108 When calling for technical assistance, please have the device installed and ready to run

Strona 12

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 109 Sealevel's commitment to providing the best I/O solutions is reflected in the Lifet

Strona 13

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 11 All SeaI/O modules have a default baud rate of 9600. If lower latencies are required, the

Strona 14

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 12 Base Modules connect to the host via one of the following interfaces:  W-Series – Wire

Strona 15

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 13 All SeaI/O modules include the same connectors and configuration options on the side of t

Strona 16

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 14 SeaI/O-410 modules provide 16 optically isolated inputs and 16 Reed relay outputs. Inputs

Strona 17

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 15 The SeaI/O-420 provides 16 optically isolated inputs and 8 SPDT Form C relay outputs. In

Strona 18

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 16 SeaI/O-430 modules provide 32 optically isolated inputs with 2500VAC RMS / 3500VDC extern

Strona 19

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 17 The SeaI/O-440 provides 32 SPST Form A dry-contact Reed relays. Reed relays offer long li

Strona 20

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 18 Control a variety of low voltage, low current devices with the SeaI/O-450. The module‟s

Strona 21

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 19 Perfect for driving industry-standard solid-state relay (SSR) racks, the SeaI/O-462 provi

Strona 22

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 2 BEFORE YOU GET STARTED ...

Strona 23

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 20 Depending upon your application, you are likely to find one or more of the following item

Strona 24

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 21 The SeaI/O-463 offers 96 bits of buffered drive TTL I/O via four internal industry-standa

Strona 25

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 22 Depending upon your application, you are likely to find one or more of the following item

Strona 26

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 23 The following accessories are suitable for use with both the SeaI/O 462 and SeaI/O 463 m

Strona 27

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 24 The IB5Q provides four discrete inputs that accept input voltages from 3.3VDC to 32VDC wi

Strona 28

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 25 Discrete 8-Position I/O Rack (Part# PB8HS) The PB8HS I/O rack can be used with up to eig

Strona 29

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 26 The IB5S provides a discrete input that accepts input voltages from 3.3VDC to 32VDC with

Strona 30

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 27 Terminal Block - 50-Pin Header – I/O Rack Simulation Module (Part# TA01) The TA01 termina

Strona 31

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 28 Figure 1. SeaI/O 462 connected to relay racks and a terminal adapter via (2) CA237 cable

Strona 32

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 29 Designed using the Maxim MAX197 successive approximation-type A/D chip, the SeaI/O-470 pr

Strona 33

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 3 CONFIGURING A WIRELESS MODULE ...

Strona 34

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 30 Hardware Selectable 0-20mA current loop (for 4-20mA devices) D/A Outputs Number of Cha

Strona 35

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 31 The SeaI/O-520 provides 8 optically isolated inputs and 8 SPDT high-current Form C relay

Strona 36

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 32 The SeaI/O-530 provides 16 optically isolated inputs and 16 open-collector outputs. Inpu

Strona 37

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 33 The SeaI/O-540 provides 32 open-collector outputs. Each open-collector output circuit inc

Strona 38

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 34 Base modules are powered from a 9-30VDC source using either the DC jack or screw terminal

Strona 39

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 35 W-Series E-Series U-Series M-Series S-Series N-Series SeaI/O-462 2.5W 2.0W 0.8W 0.5W 0.

Strona 40

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 36 The SeaMAX Suite is a collection of configuration/diagnostic utilities and software libra

Strona 41

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 37 Proceed with installing the SeaMAX Software Suite using the software disk that was includ

Strona 42

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 38 5. Type the part number for your adapter in the text box and click „Enter‟, or click on

Strona 43

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 39 1. To install the driver executable from the Sealevel disk, browse the Sealevel Systems

Strona 44

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 4 All SeaI/O modules are shipped with the following items. If any of these items is missing

Strona 45

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 40 4. In the Device Manager under „Action‟, choose „Scan for hardware changes‟. This will p

Strona 46

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 41 The Sealevel Systems configuration utility, MaxSSD, is designed to simplify the installat

Strona 47

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 42 Once the host computer is configured correctly, the “SeaI/O Configuration” tab becomes av

Strona 48

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 43 After the Get command is executed, the “Module Description” frame will display the model

Strona 49

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 44 The broadcast feature sets the Ethernet SeaI/O (E-series) module‟s TCP/IP to RS-485 tra

Strona 50

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 45 The “Digital IO” tab of MaxSSD is displayed when using Sealevel I/O devices featuring dis

Strona 51

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 46 The “A/D Inputs” tab displays the current state of the analog-to-digital channels for Sea

Strona 52

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 47 The “D/A Outputs” tab is useful for manually setting the digital to analog output voltag

Strona 53

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 48 To check basic functionality of both the A/D and D/A converters, press the “Diagnostics U

Strona 54

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 49 Following these simple steps can eliminate most common problems. 1. Read this manual th

Strona 55

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 5 Sealevel SeaI/O™ modules offer powerful data acquisition solutions that are perfect for a

Strona 56

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 50 Problem: The SeaI/O module starts up with a strange IP address (i.e., 169.254.x.x). All

Strona 57

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 51 Before configuring SeaI/O modules using MaxSSD, you must first select a device addressing

Strona 58

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 52 A “stack” or “chain” of SeaI/O modules, connected via the pass-through connectors or sc

Strona 59

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 53 Once the SeaMAX Software Suite has been installed successfully and you have decided which

Strona 60

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 54 Once you have successfully connected and communicated with a “base” module, you can begin

Strona 61

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 55 This section applies only to Wireless (W-series) SeaI/O modules. For all other SeaI/O mo

Strona 62

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 56 Verify that SeaMAX software has been installed successfully and that a wireless SeaI/O mo

Strona 63

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 57 Start by opening the Windows Wireless Network Connection utility, which can be found by c

Strona 64

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 58 The Wireless Network Connection window will now display “Limited or no connectivity” next

Strona 65

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 59 Start the Ethernet Config utility (Start  All Programs  Sealevel SeaMAX  Ethernet Conf

Strona 66

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 6  Choice of Connectivity: o Wireless (802.11b/g) o Ethernet o USB o RS-485 o RS-232

Strona 67

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 60 You must now change the IP Address of your wireless adapter to match the subnet (first 3

Strona 68

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 61 In the Internet Protocol (TCP/IP) Properties window, click the radio button for „Use the

Strona 69

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 62 To confirm that the IP Address for your wireless adapter was changed successfully, reopen

Strona 70

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 63 Now that you can communicate with the wireless SeaI/O module, the Wireless Configuration

Strona 71

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 64 You can now change the Network SSID, Topology, Channel, and Security Settings to match yo

Strona 72

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 65 The following options are available in the Wireless Configuration window: Wireless Confi

Strona 73

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 66 using the steps described at the beginning of this section. Depending on the country use

Strona 74

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 67 Open the Wireless Network Connection utility again (Start  right-click on My Network Pla

Strona 75

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 68 To complete the configuration, you need to change the IP Address of your wireless adapter

Strona 76

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 69 Start MaxSSD (Start  All Programs  Sealevel SeaMAX  MaxSSD) and select Ethernet in the

Strona 77

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 7 Wireless 802.11b & 802.11g SeaI/O-410W – 16 Optically Isolated Inputs/16 Reed Relay

Strona 78

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 70 Set the slave ID of the “base” wireless SeaI/O module using the rotary switch or software

Strona 79

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 71 SeaI/O wireless (W-series) modules are compatible with 802.11b and 802.11g wireless netwo

Strona 80

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 72 Channel Frequency (GHz) North America Europe Japan France Spain 1 2.412 OK OK OK No No 2

Strona 81

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 73 This section applies only to Ethernet (E-series) SeaI/O modules. For all other SeaI/O mo

Strona 82

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 74 Start MaxSSD (Start  All Programs  Sealevel SeaMAX  MaxSSD) and choose the correct IP

Strona 83

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 75 Before recovery begins, make certain that the PC and Ethernet SeaI/O module are on the sa

Strona 84

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 76 The initial version of the firmware does not support theses Advanced Features. These unit

Strona 85

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 77 Since SeaIOCU.exe must be executed from a command prompt, the easiest way to use it is t

Strona 86

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 78 Disabling the Rotary Address Switch and Limiting Software Address Range Selection is not

Strona 87

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 79 Limiting Expansion Port Communications Data Rate Selection is not available on older Sea

Strona 88

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 8 RS-232 SeaI/O-410S – 16 Optically Isolated Inputs/16 Reed Relay Outputs SeaI/O-420S – 16

Strona 89

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 80 A copy of these instructions is included with the SeaI/O-463 module and can also be downl

Strona 90

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 81 Remove the terminal block from the left side and then remove the two black screws from ea

Strona 91

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 82 Replace the metal strain relief. Start both screws and tighten only until snug. Do not

Strona 92

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 83 The SeaI/O-470 module ships factory configured with the D/A outputs set for 0-10V and cur

Strona 93

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 84 This detail image of the right side of the SeaI/O-470 circuit board shows the locations o

Strona 94

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 85 The (E1) and (E2) jumpers (shown in the orange boxes on the previous page) configure the

Strona 95

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 86 All SeaI/O modules include two RS-485 pass-through connectors on the left side of the uni

Strona 96

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 87 Optically isolated inputs are arranged such that each group of four shares a single commo

Strona 97

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 88 The SeaI/O-462 and SeaI/O-463 use 74ABT245 octal bi-directional transceivers to provide T

Strona 98

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 89 Power & Commons +5V 63, 74 Commons 41 – 58, 64 – 73

Strona 99

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 9 Depending on the interface type, your SeaI/O module may include additional accessories. In

Strona 100 - SeaI/O Manual

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 90 For easy connection to industry-standard solid-state relay racks, Sealevel manufactures a

Strona 101

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 91 The SeaI/O-463‟s 96 digital I/O channels are accessed via four industry-standard 50-pin h

Strona 102

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 92 The SeaI/O-470 supports single-ended, differential, and current loop A/D inputs. Single-

Strona 103

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 93 The SeaI/O-470‟s A/D channels can also be configured to provide up to eight 12-bit curren

Strona 104

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 94 The SeaI/O-470 modules include eight optically isolated inputs that are arranged such tha

Strona 105

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 95 Optically isolated inputs are arranged such that each group of two shares a single common

Strona 106

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 96 The SeaI/O-530 modules include 16 optically isolated inputs that are arranged such that e

Strona 107

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 97 SeaI/O S-Series (RS-232) modules have an RJ45 connector on the face of the enclosure.

Strona 108

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 98 SeaI/O Mounting Kit (Part# KT122) Expanding your I/O count is as simple as adding N-Seri

Strona 109

©Sealevel Systems, Inc. SL9049 - 11/2010 SeaI/O Manual 99 SeaI/O USB modules integrate a patent-pending SeaLATCH USB port, which is fully compatibl

Komentarze do niniejszej Instrukcji

Brak uwag